BMXDRA0805H Schneider Electric BMXDRA0805H Programmable Logic Controller - Product View | Vibocnc
PLC Programming Software

Schneider Electric BMXDRA0805H Programmable Logic Controller

Product information

$850.26

SKU: BMXDRA0805H

Alternate: BMXDRA0805H

Brand
Schneider Electric
Part Number
BMXDRA0805H
Warranty
12 months
Lead time
4-5 DAYS
In Stock- Ready to ship
Worldwide Shipping
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric BMXDRA0805H Programmable Logic Controller Overview Schneider Electric BMXDRA0805H is a programmable logic controller supplied for industrial automation maintenance, breakdown replacement and retrofit projects. It is used for machine sequence control and system coordination, where the CPU or control series and option configuration determine a correct replacement. Because Schneider Electric assemblies differ between machine builds, the model is confirmed against the original unit label before dispatch. Typical applications - It is used for machine sequence control and system coordination, where the CPU or control series and option configuration determine a correct replacement. - Preventive maintenance and urgent breakdown replacement - Service inventory for machine tool and automation maintenance teams Why buy from Vibocnc - Multi-brand industrial automation parts supplier - Stocked inventory with fast handling - Shipping worldwide with tracking - Model verification and technical confirmation before dispatch

Technical Specifications

SKU
BMXDRA0805H
Brand
Schneider Electric
Part Number
BMXDRA0805H
Category
PLC Programming Software
Condition
new
Warranty
12 months
Country of Origin
China
Packaging
New surplus, never used
Status LED
1 LED (Green) module operating (RUN) 1 LED per channel (Green) channel diagnostic 1 LED (Red) module error (ERR) 1 LED (Red) module I/O
Characteristic
Value(s)
Product Weight
0.320 lb(US) (0.145 kg)
MTBF reliability
2119902 H
Range of Product
Modicon X80
Discrete output type
Relay
Electrical durability
AC-15 100000 cycles 132 VA 200...240 V 158 °F (70 °C) AC-15 100000 cycles 220 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-12 1000000 cycles 110 VA 110...120 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 132 VA 200...240 V 158 °F (70 °C) AC-12 1000000 cycles 220 VA 200...240 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 30 VA 48 V 158 °F (70 °C) AC-12 1000000 cycles 50 VA 48 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 66 VA 110...120 V 158 °F (70 °C) AC-15 1000000 cycles 110 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-15 1000000 cycles 66 VA 200...240 V 158 °F (70 °C) DC-12 1000000 cycles 14.4 W 24 V 158 °F (70 °C) DC-12 1000000 cycles 24 W 24 V -13…140 °F (-25…60 °C) DC-13 1000000 cycles 14.4 W 24 V 158 °F (70 °C) DC-13 1000000 cycles 24 W 24 V -13…140 °F (-25…60 °C) AC-15 10000000 cycles 10 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 10000000 cycles 10 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-15 10000000 cycles 6 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 10000000 cycles 6 VA 200...240 V 158 °F (70 °C) AC-15 150000 cycles 110 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 150000 cycles 66 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 1500000 cycles 30 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 1500000 cycles 50 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 2000000 cycles 14.4 VA 48 V 158 °F (70 °C) 0.35) AC-15 2000000 cycles 24 VA 48 V -13…140 °F (-25…60 °C) 0.35) DC-13 2000000 cycles 10 W 24 V -13…140 °F (-25…60 °C) DC-13 2000000 cycles 6 W 24 V 158 °F (70 °C) DC-12 300000 cycles 24 W 24 V 158 °F (70 °C) DC-12 300000 cycles 40 W 24 V -13…140 °F (-25…60 °C) AC-15 3000000 cycles 30 VA 200...240 V 158 °F (70 °C) AC-15 3000000 cycles 50 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-12 500000 cycles 110 VA 48 V -13…140 °F (-25…60 °C) AC-12 500000 cycles 132 VA 110...120 V 158 °F (70 °C) AC-12 500000 cycles 220 VA 110...120 V -13…140 °F (-25…60 °C) AC-12 500000 cycles 66 VA 48 V 158 °F (70 °C) AC-15 5000000 cycles 10 VA 48 V -13…140 °F (-25…60 °C) 0.35) AC-15 500000 cycles 14.4 VA 24 V 158 °F (70 °C) 0.35) AC-15 500000 cycles 24 VA 24 V -13…140 °F (-25…60 °C) 0.35) AC-15 5000000 cycles 6 VA 48 V 158 °F (70 °C) 0.35) AC-12 700000 cycles 30 VA 24 V 158 °F (70 °C) AC-12 700000 cycles 50 VA 24 V -13…140 °F (-25…60 °C)
Insulation resistance
> 10 MOhm 500 V DC
Discrete output number
8 EN/IEC 61131-2
Power dissipation in W
2.7 W
Discrete output voltage
24...240 V 19...264 V AC 12...24 V 10...34 V DC
Response time on output
< 10 ms activation < 8 ms deactivation
Minimum switching current
10 mA 5 V DC
Product or Component Type
Discrete output module
Output overload protection
Use 1 fast blow fuse per channel or group of channel
Typical current consumption
79 mA 3.3 V DC
Product Specific Application
For severe environments
Output overvoltage protection
Use discharge diode on each output DC Use RC circuit on each output AC Use ZNO surge limiter on each output AC
Output short-circuit protection
Use 1 fast blow fuse per channel or group of channel
[Ith] conventional free air thermal current
3 A

Frequently Asked Questions